Skip to main content
Measurement Science ReviewVolume 14, Issue 5, 1 October 2014, Pages 285-293

Automated acquisition of proximal femur morphological characteristics(Article)(Open Access)

  • Tabakovic, S.,
  • Zeljkovic, M.,
  • Milojevic, Z.
  Save all to author list
  • Faculty of Technical Sciences, University of Novi Sad, Trg Dositeja Obradovica 6, Novi Sad, 21000, Serbia

Abstract

The success of the hip arthroplasty surgery largely depends on the endoprosthesis adjustment to the patient's femur. This implies that the position of the femoral bone in relation to the pelvis is preserved and that the endoprosthesis position ensures its longevity. Dimensions and body shape of the hip joint endoprosthesis and its position after the surgery depend on a number of geometrical parameters of the patient's femur. One of the most suitable methods for determination of these parameters involves 3D reconstruction of femur, based on diagnostic images, and subsequent determination of the required geometric parameters. In this paper, software for automated determination of geometric parameters of the femur is presented. Detailed software development procedure for the purpose of faster and more efficient design of the hip endoprosthesis that ensures patients' specific requirements is also offered.

Author keywords

Automated acquisitionHipMorphological characteristics

Indexed keywords

Engineering controlled terms:AutomationDiagnosisGeometryHot isostatic pressingSoftware designSurgery
Engineering uncontrolled terms3D reconstructionAutomated acquisitionDiagnostic imagesEfficient designsHip arthroplastiesHip endoprosthesisMorphological characteristicProximal femur
Engineering main heading:Bone

Funding details

Funding sponsor Funding number Acronym
Ministarstvo Prosvete, Nauke i Tehnološkog Razvoja35025,TR 35025MPNTR
  • 1

    ACKNOWLEDGMENT This work was supported by the Ministry of Education, Science and Technological Development of the Republic of Serbia, project No. TR 35025

  • ISSN: 13358871
  • Source Type: Journal
  • Original language: English
  • DOI: 10.2478/msr-2014-0039
  • Document Type: Article
  • Publisher: Slovak Academy of Sciences - Inst. Measurement Science


© Copyright 2021 Elsevier B.V., All rights reserved.

Cited by 3 documents

Chen, H. , Pei, Y. , Xiao, L.
An Automatic Orientation Method of Tibial Sagittal Plane Based on Anatomical and Statistical Features
(2023) Proceedings - 2023 16th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics, CISP-BMEI 2023
Djuricin, A. , Tabaković, S. , Zeljković, M.
Determination of spatial position of tibial graft using X-ray images after anterior cruciate ligament reconstruction
(2023) Vojnosanitetski Pregled
Tabaković, S. , Zeljković, M. , Milojević, Z.
Design of custom made prosthesis of the hip
(2019) Tehnicki Vjesnik
View details of all 3 citations
{"topic":{"name":"Hip; Prosthesis; Finite Element Method","id":1913,"uri":"Topic/1913","prominencePercentile":91.2619,"prominencePercentileString":"91.262","overallScholarlyOutput":0},"dig":"79ca7ad8fa8e4c7bd2b2d07dc519ab92e61ee6d816a5bae781d733cb6e48ad98"}

SciVal Topic Prominence

Topic:
Prominence percentile: